UNIVERSAL UNIT X10 S110125 Domótica:
Modules Domótica X10
That it is X10? 
34,35-Euro.

Module that controls the dull ignition and of apparatuses of low voltage or contacts without tension by means of a relay that admits a load max. of 5A to 24V. It has two ways of operation; Continuous and Momentary. It also works in manual and it can operate as an auxiliary timbre or both things simultaneously. It receives you order of any system of domótica x10.
In the way “Continuous” (Continuous) the relay or the sound stays fixed when the STARTUP CMD occurs or extinguished (“ON/OFF”).
In way “Momentary” (Momentary) when order “ON” occurs, the relay or the sound activate during 2 seg. prox. And they are deactivated after automatic form. If order “OFF” occurs, will be ignored.
The module has bellboys of “ON” and “OFF” (Ignited and Extinguished) for its activation manual.
APPLICATIONS
- Control of ignition/extinguished of apparatuses of low voltage or contact without tension by means of a relay. - It can be used of momentary form (with ignition lag/extinguished in 2 seconds) - A warning device Includes that announces its operation. - Action of ignition/extinguished of apparatuses with action on free relays of tension or low voltage. - Motor, electroválvulas, boilers of heating, etc.
OPERATION
1. With a screwdriver, to select the code of House and Unit. 2. To connect the application of low voltage in the Tips of module, and to fit them with a screwdriver (max. 24Vdc, 5A). 3. To connect the module to the mains. 4. It selects selectors in the position wished for his operation:
Left selector: 1. `Continuous' (Continuous): the relay or the sound stays fixed when the STARTUP CMD occurs or extinguished (“ON /OFF”). 2. `Momentary' (Momentary): when order “ON” occurs, the relay or the sound, activates during 3 - 5 seg. approx and they are deactivated after automatic form. If order “OFF” occurs, will be ignored.
Right selector: 1. Sounder Only (only the siren): When we send to him a STARTUP CMD to the module this will only act on the siren. 2. Sounder & Relay (siren and relay): In this position the module will act on the relay and the siren. 3. Only relay (Only relay): In this position the module would only act on the relay. The relay of contact closing admits a fully factored load of 5 A. to 24 VDC.
TO NEVER CONNECT 220V IN the TERMINALS!
Engineering specifications
| Tension of feeding |
230 V +-10%/50 Hertz |
| Power |
5A - 24VDC |
| Emission staff |
It fulfills the norm IN 50081-1 |
| Emission EMS |
It fulfills the norm IN 50082-1 |
| Electrical security |
It fulfills the norm IN 60950 and 60065 |
| Sensitivity of signal |
15 mVpp min 50 mVpp max to 120 kHz |
| Impedance of entrance |
>55 ohm (120 L-N) to Khz |
| Temperature operation |
-10ºC to 50ºC |
| Dimensions |
90 xs 55 xs 64 mm |
| Current feeding |
20 mA. |
Related products
PIDALO NOW AND RECIBALO TOMORROW!
34,35-Euro. 39,85 € with IVA

|
TO SEE MAS PRODUCTS DE Módulos Domótica X10
UNIVERSAL UNIT X10 S110125
Domótica: It controls any apparatus noncompatible X10.
|