MICROUNIT APPARATUS + 2 DIRECTIONS AWM2 S110325 Unit of apparatus and transmitter of 2 directions x10
Modules Domótica X10
That it is X10? 
71,59-Euro.

The micromodule settles inside cajillo of the normal switches of wall. Besides sending and controlling 2 directions x10, this micromodule incorporates an unit of normal apparatus, reason why he is able to connect and to disconnect any apparatus locally. The micromodule allows to use the present switches to send you order x10 being avoided therefore having to change the design of the switches by other specific ones of domótica. Measures 46 xs 46 xs 16 mm.

The micromodule settles in cajillo of the switches thanks to its small size.
OPERATION
The micromodule incorporates a relay able to connect and to disconnect up to 2200 W of resistivas loads or 600W of inductive loads or capacitativa (motor fluorescent, etc), reason why can be used with the majority of the apparatuses and electric home appliances of the home. In addition they are possible to be connected up to two external pulsers that act you two-way traffic order sending them of different dull ignition and to x10. Micromodules AWM2 respond to you order ignited X10 of ignition, dull, all the lights and all dull one. The first pulser, acts on the unit of internal apparatus igniting it or extinguishing it, besides sending the order to the corresponding direction x10, whereas the second pulser only sends the X10 order through the installation of 220v. The programming and allocation of the X10 directions of the micromodule can be established with the aid of any controller or order able to send you order X10.
INSTALLATION
The installation of the micromodules will have to become exclusively by people with basic knowledge of electricity, able to at least understand and to include/understand the difference between Neutral, Phase and Load.
Before beginning the installation it remembers to disconnect the current of the circuit in which this working or better even totally disconnects the general current of all the installation

1 Step. It disassembles the mechanism of the switch in whom it wants to place the micromodule and it both locates feeders of 220V and the cable that goes direct to the load (normally a lamp). It there would be 2 cables, they mean that only they are the connections of the load and one of the poles of 220V (would have to be the load, but it is necessary to verify it), reason why will be necessary to bring from the box of registry a cable but with the other pole of 220V, since the micromodule needs to work the phase and the neutral one.

2 Step. Interrupter/es connects cables of the micromodule to /los as it is in the illustration considering that the pulser or switch must act on the neutral one and not on the phase. The blue cable of the connected micromodule this to the entrance of the neutral one and therefore is common for the switches or the pulsers that go to use. In the illustration is a mechanism with an interrupting one doubles, but it can be also used with one simple one, or two independent switches. The cable of phase and the load, must be connected in the tips marked with L.

3 Step. Once all this connected, returns to connect the current and comes to program the micromodule, beating for it on the pulser “Prog” with the aid of a screwdriver. It follows the instructions of the section PROGRAMMING to realize this process.

4 Step. Once programmed the micromodule, it returns to place with well-taken care of the mechanism of the switch in cajillo and places the cover and corresponding frame finally.
PROGRAMMING
In order to program the micromodule it is necessary to count on the aid of some control or X10 controller. It can use a control by radio frequency like control 8 in 1 along with a receiver of radio frequency, or a controller with direct connection to the network.
In order to enter the programming way, “prog” is necessary to press the button during at least 3 seconds. The LED will ignite indicating that this in programming way. The micromodule will leave the programming way if it does not receive any order in 60 seconds. In order to also leave the programming way “prog” can can press the button briefly, and so the LED will go out.
In order to program the base address of the micromodule, it would be enough with sending commando to him ON to that direction being the micromodule in the programming way For example to program the B3 direction as direction x10 bases of the micromodule, first puts the micromodule in the programming way, and next with a controller or control that has the code of house “B”, we pressed on the button “3 ON”. The micromodule will respond to the received commando making blink the LED 2 times.
Also it is possible to be programmed additional functions as to respond to you order “all the ignited lights” and “to extinguish everything”. For defect, unit is not responsible to any of these you order.
In order to program the function “All the ignited lights” the micromodule in way is put programming and continuation with a control or controller that have the same code of house that the micromodule, is sent the commando “all the ignited lights”. The micromodule responds making blink the LED 6 times.
IMPORTANT It always programs the first base address of the micromodule and soon it programs the other secondary functions. Whenever a base address is programmed, all the secondary functions adjust to their values by defect.
| By Defect |
Programmable option |
Commando |
Sparkles LED |
| A1 direction |
A1 directions of P16 |
2 Xs Direction |
2 |
| It does not respond “to All the ignited lights” |
It responds “to All the ignited lights” |
2x “All lights On” |
6 |
| It does not respond “All dull one” |
It responds “All dull one” |
2x “All Units Off” |
8 |

Example of application of a micromodule AWM2
Engineering specifications
| Tension of feeding |
230 V 50 Hertz |
| Power of internal unit |
2200W Resistivas/600W capacitativas |
| Emission staff |
It fulfills the norm IN 50065-2-1 |
| Emission EMS |
It fulfills the norm IN 50065-4-1 |
| Electrical security |
It fulfills the norm IN 60669-2-1 and IN 60669-2-2 |
| Sensitivity of signal |
25 mVpp… 6Vpp to 120 kHz |
| Relation signal/noise |
1,35:1 |
| Temperature operation |
-10ºC to 50ºC |
| Connections |
2.5 mm |
| Current feeding |
< 30 mA. Capacitativo |
FAMILY DE MICROMODULOS X10
| TYPICAL SUMMARY OF MICROMODULOS |
| Reference |
S110325 |
S110329 |
S110320 |
S110323 |
S110327 |
| MODEL |
AWM2 |
LWM1 |
TMA4 |
TMD4 |
AW12 |
| X10 communication |
Bidirectional |
Unidirectional |
| Type of commutation |
Inductive relay 16A 2200W Lamps 3A |
Halogenous regulator 250W Lamp 200W lowers tension |
- |
- |
Relay 16A. 2000W inductive lamp 3A |
| Regulating Light |
No |
If |
No |
No |
No |
| You order Received |
On/Off. All on lights. All the Off lights |
| You order Transmitted |
On/Off |
On/Off/atenuacion/brillo |
On/Off |
On/Off/Brillo/Atenuación |
- |
| The load is connected in unit |
If |
No |
If |
| Quiet relay |
If |
- |
No |
| Entrances/X10 exits |
2 |
1 |
4 |
4 |
1 |
| Type interrupting |
Switches or Pulsers |
Pulsers |
Switches |
Pulsers |
Pulsers |
| Connection pulsers a |
Neutral |
Phase 220V |
| Dimensions |
46 xs 46 xs 16 mm. |
| Ignited LED/programming |
If |
No |
| Feeding |
230V 50Hz |
| Consumption |
< 30mA |
< 20mA |
| Functions |
Unit Apparatus 2 directions |
Unit Lamp 1 direction |
Transmitter 4 Directions Apparatuses |
Transmitter 4 Directions Lamps |
Unit Apparatus 1 direction |
Related products
PIDALO NOW AND RECIBALO TOMORROW!
71,59-Euro. 83,05 € with IVA

|
TO SEE MAS PRODUCTS DE Módulos Domótica X10
MICROUNIT APPARATUS + 2 DIRECTIONS AWM2 S110325
Unit of apparatus and transmitter of 2 directions x10
|